New Features in Service Pack 6

Overview of general new features in NeuroCheck 5.1

Overview of new features in Service Pack 5

Download of current Service Pack

The sixth service pack for NeuroCheck 5.1 introduces a number of new hardware and software features. On this page we will present the major new features, for details please refer to file History.txt, as usual.

  • The driver for Hilscher CIF Field Bus Devices has undergone a revision which incorporates feedback and various suggestions from our customers.

    During initialization of the field bus device during start-up, NeuroCheck waits for a configurable time period for a response of the field bus communication partner, usually the bus master. So far, NeuroCheck could only use a field bus device when this communication was working properly. Now, the device can be accessed independently of a working communication. This simplifies the system set-up and configuration of check routines, especially if the communication partner is not available during set-up.

    After any bus communication error, NeuroCheck will automatically try to resume the broken communication. The time period for trying to resume communication is limited by an own time-out for I/O commands.

    For a Profibus slave board, NeuroCheck can read out the current I/O configuration of the board as previously defined in the Hilscher configuration tool. This information is used to display only the configured number of input and output bits, which improves the overview for the user.

    You can find various information about the installed hardware and its configuration in the device properties or the info dialog, which can be of great help for diagnostics, just as the new XML logging facility.

    The new on-line help system for the driver gives valuable information regarding installation and configuration of the field bus communication.

    In theory, the new driver should support any CIF field bus device, however, please refer to the list of tested hardware in the on-line help system or contact your local NeuroCheck partner.

  • Apart from the revision of the driver, some features concerning the work with I/O devices in the main program have been improved, too:
    Test dialog for the field bus communication


    A new option in General Software Settings | Compatibility allows to
    keep the current output bit image when opening and closing the Test dialog for field bus and digital I/O devices, instead of re-setting all outputs to LOW state. This can be useful to simulate the process communication, especially in Manual Mode.

    Check function Set Field Bus Output has been optimized for faster execution, especially when multiple output bits are set.

    Furthermore, a new command in the context menu of Set Field Bus Output simplifies the re-setting of all output bits to LOW state.

 
 