==============================================================
 ReadMe for Update of Baumer FWX and NCF driver for NeuroCheck
==============================================================
            === NeuroCheck 5.1 Service Pack 10 ===

This driver package supports the new Baumer NCF camera series 
with the fast FireWire-"b" interface as well as the FWX cameras.

==============================================================
I) Use of new Baumer NCF series cameras:
----------------------------------------
For a new installation of NeuroCheck NCF cameras please refer to
page "Installation" of our Baumer FWX and NCF camera series help file 
NcFwBofx.chm.

==============================================================
II) Use of Baumer FWX NeuroCheck Edition cameras:
-------------------------------------------------
(a) Update from NeuroCheck 5.1 SP9:

1. Make sure that NeuroCheck is closed.

2. Just copy the following files from the NcDriver folder into the 
   NeuroCheck installation folder (replace existing files):
   - NcFwBofx.DLL version 5.1.3043.1
   - NcFwBofx.chm 
   - FxLib.DLL version 5.0.4.12
   - SysInfo.DLL version 1.0.0.8

--------------------------------------------------------------
(b) Update from NeuroCheck 5.1 SP8 or earlier:

If you are using a Baumer FWX NC Edition camera in 
NeuroCheck 5.1 SP8 or earlier, the update to SP10 requires
also the update of the Baumer Sys driver.
In this case please proceed as follows:

1. Log on to your PC in a user profile with administrator rights.

2. Make sure that NeuroCheck is closed.

3. Update your previous NeuroCheck 5.1 installation to SP10
   by executing the self-extracting ZIP.

4. Copy the following files from the NcDriver folder into the 
   NeuroCheck installation folder (replace existing files):
   - NcFwBofx.DLL version 5.1.3043.1
   - NcFwBofx.chm 
   - FxLib.DLL version 5.0.4.12
   - SysInfo.DLL version 1.0.0.8

5. Open the Windows Device Manager (Control Panel > System > Hardware).
   
6. For each Baumer camera unter Baumer 1394 controlled devices
   open the Properties dialog and go to page Driver. Choose 
   Update Driver and search for the SysDriver folder provided with 
   this zip file. Install this driver (Baumer1394.sys version 2.0.0.157).

7. Open NeuroCheck and verify if all FWX cameras are detected 
   correctly. If not, then please reboot your PC.

==============================================================

# for further questions, please send an email to support@neurocheck.com

==============================================================
      Copyright (C) 2003 - 2007 NeuroCheck GmbH, Germany      
==============================================================